Community AlphaAlpha MUADMINS
PTPortuguês (Brasil)
Entrar
No MuADMINSConfig ScannerEnvie o zip dos seus arquivos: rates, drops, spots, limitesAbrirNo MuADMINSEncontre-nos no DiscordPeça ajuda, mostre o que está criando e converse sobre MU com outros donos de servidores.Abrir

MuADMINS

Soluções

Correções curtas para problemas comuns de servidor, cliente e site de MU Online, cada uma com a fonte e a data. “Confirmado” significa que quem perguntou disse que a correção funcionou.

206 soluções para “connect to server” · Limpar

  1. FerramentasS6

    WebEngine CMS installer: "Could not connect to database (1)" at the database step with MSSQL Server 2008 (PDO ODBC, XAMPP)

    1. In this case the game files connected fine but the WebEngine installer kept failing on the database step, with no error in the SQL logs or the Windows event log. 2. The cause was a con...

    ✓ Confirmado pelo autor do tópicoRaGEZONE · 2023-10-06
  2. FerramentasOutros server files

    Launcher auto update (Titan Tech SCF ConnectServer) never downloads the patch from a hosting FTP account

    1. The update FTP is set in the ConnectServer SCF_Config.ini, sections [FtpServerInfo] and [HttpServerInfo] (SCFAddress, SCFPort, SCFID, SCFPASS), with SCFClientVersion and SCFVersionFile...

    ✓ Confirmado pelo autor do tópicoRaGEZONE · 2015-02-23
  3. FerramentasWebZen 97d / 99b97d

    MuEditor 2.1 / MuMaker: 'SQL Connection failed' with a 97d+99i server, even when run as administrator

    1. Running the editor as administrator did not help. 2. The editors connect through the ODBC data sources of the server (MuOnline, MuOnlineJoinDB and so on), so these must be registered c...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2016-05-07
  4. Cliente do jogoMuEmu / LouisS5.2

    Main 5.2 (Louis) with MuServer Update 15: 'WriteValidation > ProtocolSend Connect [0] Read Header Fail:End of file' when the client connects

    1. The asker fixed it (with help from son1xx2 on RaGEZONE) by building both the GameServer and the main without the new protocol system. 2. In the server source set #define NEW_PROTOCOL_S...

    ✓ Confirmado na issueGitHub (LouisEmulator/Main5.2) · 2022-11-23
  5. Ferramentas

    Titan Editor: cannot connect to the MU database to create accounts (single MuOnline database)

    1. Open the Titan Editor config. With only one database (MuOnline) both ODBC names point to it: [Connection] ODBC=MuOnline, ODBC_Me=MuOnline, User=sa, Password=yourpass, SQLServer=(local)...

    ✓ Confirmado pelo autor do tópicoRaGEZONE · 2013-09-25
  6. Configuração do servidorOpenMU

    OpenMU: a player stays 'already connected' after a dropped connection and cannot log in again, even with the right password

    1. The old session stays registered while the TCP connection to OpenMU is still open. With the web client the WebSocket proxy keeps that connection alive, so every new login gets AccountA...

    ✓ Confirmado na issueGitHub (MUnique/OpenMU) · 2026-10-07
  7. FerramentasMuEmu / Louis

    MainInfo and Louis files on a local PC: the game cannot connect to 127.0.0.1 (nothing on 127.0.0.1 works on that PC)

    1. Use the network IP of the PC (the LAN address) instead of 127.0.0.1. 2. Put that IP in MapServerInfo.dat, in the ConnectServer configuration and in MainInfo. 3. Common.dat can stay wit...

    ✓ Confirmado pelo autor do tópicoCreandoMU · 2021-03-26
  8. FerramentasMuEmu / Louis

    MuEditor and MuEditorDeCuenta (account editor) cannot connect to SQL Server on the VPS, both show connection errors at start

    1. Configure both editors with the IP of your VPS, the SQL user sa and its password. 2. Open the SQL Server port (1433 unless you changed it) in the Windows Firewall of the VPS. 3. In SQL...

    ✓ Confirmado pelo autor do tópicoCreandoMU · 2023-01-01
  9. Configuração do servidorMuEmu / LouisSeason 6 (Louis)

    Two accounts always say they are already logged in, but they are not in game and cannot be disconnected.

    1. The online state is kept by the JoinServer. 2. Use the JoinServer option to disconnect accounts. 3. Then the account can log in again.

    ✓ Confirmado pelo autor do tópicoCreandoMU · 2021-01-31
  10. Configuração do servidorS3E1 (1.04H)

    GameServer says "Please input authentication server address and port number. => LoginServer connect fail" (Season 3 Episode 1, 1.04H)

    The server starter did not pass the JoinServer and DataServer addresses to the GameServer. 1. Open ServerStartUp.ini. 2. Give the JoinServer the parameters /p55970 /ca:ip: /cp55557. 3. Gi...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2008-06-03
  11. Cliente do jogo97d+99i

    Disconnect when entering my 97d+99i server after changing the main.exe settings with a Main Editor

    For the 97d+99i files main.exe must not be edited. 1. Put back the original main.exe of the matching client. 2. Connect through the launcher set to your server address. 3. Log in again.

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2008-07-04
  12. Configuração do servidor

    All servers start fine, but in game after pressing Connect it says "You are disconnected from the server"

    The ConnectServer files still had a wrong IP. 1. Edit these files and put your local IP in each: D:\MuServer\CS\Connectserverlist, D:\MuServer\CS\Data\Connectserverlist, D:\MuServer\CS\Da...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2009-05-24
  13. Configuração do servidor

    "login server connect fail" when the server starts the GameServer

    The confirmed cause was an IP address that was not changed in one of the server configs. 1. Go through the configs of ConnectServer, JoinServer, DataServer and GameServer. 2. Replace ever...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2009-11-04
  14. Configuração do servidor

    How to change the ConnectServer port 44405, and login fails after changing it

    1. Use the BoR Team ConnectServer, which has ini files with a port option, and set the new port there. 2. Put the same port in the launcher. 3. If login still fails, open MuServer\Connect...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2010-12-21
  15. Configuração do servidor97d+99i

    GameServer error at start with DarkMaster 97d+99i Beta 13 files, fixed by turning off the EventChip server connection

    1. Open Data\commonserver.cfg. 2. Find EventChipServerConnect = 1 and change it to EventChipServerConnect = 0. 3. Restart the GameServer.

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2011-04-23
  16. Configuração do servidor

    Disconnect when entering my own server behind a router, although it worked before (after a Windows startup problem)

    The PC got a different local IPv4 address, so the router's DMZ still pointed to the old one. 1. Open cmd and run ipconfig /all; note the IPv4 address. 2. In the router, set the DMZ (or th...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2012-04-30
  17. Configuração do servidorS2

    Client disconnects after choosing the server; the client log shows it connecting to someone else's IP (10.0.0.33, port 55901) with Pinkof Season 2 files

    The server files and the client still pointed to the IP of the person who packed them. 1. Put your own IP in the ConnectServer server list config. 2. Put your own IP in the JoinServer con...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2015-02-13
  18. Configuração do servidor97d+99i

    "error-L1 : CloseClient INVALID_SOCKET": after some time online the GameServer disconnects all players (97d+99i, after moving from Windows Server 2003 to Windows Server 2012 R2)

    Reinstalling Windows, all updates and compatibility modes did not help; the fix was the newer DLL for the files. 1. Download the newer DLL that the developer uploaded for these 97d+99i fi...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2017-02-14
  19. Site

    Website error "Fatal error: Call to undefined function mssql_connect()" (XAMPP 1.7.7, SQL Server 2008, DarksWeb 0.3)

    New XAMPP builds no longer have the mssql_* functions these old sites use. 1. Install XAMPP 1.7.1 (said to be the last one with mssql_*), or add code that defines those functions to the s...

    ✓ Confirmado pelo autor do tópicoDarksTeam · 2019-02-07
  20. Siteany

    WebEngine sidebar shows players online when nobody is connected

    The online count comes from MEMB_STAT, and some accounts stayed marked as connected there. 1. With the game server closed, clear the stuck online flag in MEMB_STAT (for example: UPDATE ME...

    ✓ Confirmado pelo autor do tópicoTUServerMU · 2021-05-30

Vídeos no MUTube

Mais vídeos de “connect to server”

Ainda com problema? Pergunte ao Assistente MU Buscar no MuGPS

MuADMINS Community Alpha: grátis, feito pela comunidade e em desenvolvimento ativo.