Titan Editor: cannot connect to the MU database to create accounts (single MuOnline database)

✓ Confirmată de autorul topicului

Unealtă: Titan Editor

  1. Open the Titan Editor config. With only one database (MuOnline) both ODBC names point to it: [Connection] ODBC=MuOnline, ODBC_Me=MuOnline, User=sa, Password=yourpass, SQLServer=(local).
  2. Set UseODBC=1 (with 0 it could not connect here) and make sure the ODBC source named MuOnline exists.
  3. In [Common] set UseMD5=1 or 0 to match your server (try both if you do not know whether MD5 passwords are on).
  4. If a created account does not show in the editor list, the editor does not match your database structure: use the editor made for your files.

Autorul topicului a confirmat că a funcționat.

Cuvintele originale (engleză)

“UseODBC=0 << BEFORE ( when I set to 1 it works.”

Autorul topicului, 2013-09-25 (cuvintele originale)