MuADMINS
Soluzioni
Fix brevi per i problemi comuni di server, client e siti web di MU Online, ognuno con la sua fonte e la sua data. “Confermato” significa che chi ha fatto la domanda ha detto che il fix ha funzionato.
2 soluzioni per “mu maker 1.12” · Azzera
MuMaker 1.12: "No connection could be made because the target machine actively refused it, error 0" or "error 40" when connecting
1. Open SQL Server Configuration Manager > SQL Server Network Configuration > Protocols for MSSQLSERVER. 2. Set TCP/IP to Enabled. 3. In TCP/IP Properties, IP Addresses tab: set Enabled t...
✓ Confermato dall'autore della discussioneRaGEZONE · 2017-08-08MuMaker 1.12 / 1.13: warehouse and inventory items do not load on a Season 4.5 database (other MuMaker builds fail too)
1. The cause is the database layout of these files, not the MuMaker install: reinstalling, MSSQL 2005 vs 2014, an Items column set to varbinary(1920) and five other MuMaker builds gave th...
✓ Confermato dall'autore della discussioneRaGEZONE · 2021-04-11
Risultati per alcune delle tue parole
Queste soluzioni contengono alcune delle parole di “mu maker 1.12”:
MuMaker: "Cannot open database "MuOnline" requested by the login. The login failed" on SQL Server 2005 Express
1. Enable the sa login: Management Studio > Security > Logins > sa > Properties: untick "Enforce password policy", set a password; on the Status page tick Grant and Enabled. 2. Server Pro...
✓ Confermato dall'autore della discussioneRaGEZONE · 2012-08-18MuMaker 1.09: worked yesterday, now fails to start after the antivirus (Avast) removed a file
1. The antivirus cleaned or quarantined a MuMaker file, so the program is broken. 2. Turn the antivirus (Avast) off, reinstall MuMaker, and start it again.
✓ Confermato dall'autore della discussioneRaGEZONE · 2011-05-09MuMaker: "MuMaker has stopped working" on Windows 7 although .NET Framework is installed
1. Check the Windows regional settings: open Region (Regional and Language Options) > Administrative > "Language for non-Unicode programs". 2. Here it was set to Japanese, which made MuMa...
✓ Confermato dall'autore della discussioneRaGEZONE · 2011-03-02MuMaker: "Login failed for user 'sa'" although the server runs and the password is right (only one MuMaker build works)
1. Check that the sa login has rights on the MU databases and that the password in the MuMaker Config.ini is right. 2. If it still says login failed, the MuMaker build does not fit your s...
✓ Confermato dall'autore della discussioneRaGEZONE · 2011-06-30MuMaker (custom Season 6 build): an error pops up at start, even after installing .NET Framework 3.5 and running as admin
1. Install .NET Framework 3.5 and run MuMaker as administrator (this alone did not fix it here). 2. Install a clean MuMaker build (the one linked in the reply) with Run as administrator....
✓ Confermato dall'autore della discussioneRaGEZONE · 2012-01-14MuMaker: creating an account fails with "Disallowed implicit conversion from data type varchar to data type varbinary ... column 'memb_pwd'"
1. The error means MEMB_INFO.memb_pwd is a varbinary column: your database stores MD5 passwords. 2. Enable MD5 in the MuMaker settings and create the account again. 3. A reply also sugges...
✓ Confermato dall'autore della discussioneRaGEZONE · 2011-12-06MuMaker: Rage Fighter gloves and weapons are missing, only helm, armor, pants and boots are listed
1. Rage Fighter gloves are weapons for that class, so MuMaker does not list them under Gloves. 2. Open the sword (weapons) category in the item maker: the RF gloves are there.
✓ Confermato dall'autore della discussioneRaGEZONE · 2012-05-19MuMaker: "MuMaker has stopped working" right after it opens (Season 6 Episode 3)
1. Install the .NET Framework versions MuMaker needs: 3.0, 3.5 and 4.0. 2. Start MuMaker again. The same fix is reported in other threads after reinstalling Windows (MuMaker gave an error...
✓ Confermato dall'autore della discussioneRaGEZONE · 2014-04-11