MuMaker 1.12: "No connection could be made because the target machine actively refused it, error 0" or "error 40" when connecting

✓ Kinumpirma ng nagsimula ng topic

Tool: MuMaker 1.12

  1. Open SQL Server Configuration Manager > SQL Server Network Configuration > Protocols for MSSQLSERVER.
  2. Set TCP/IP to Enabled.
  3. In TCP/IP Properties, IP Addresses tab: set Enabled to Yes and TCP Port to 1433 for all entries.
  4. Click OK, restart the MSSQLSERVER service and run MuMaker again.

Kinumpirma ng topic starter na gumana ito.

Orihinal na salita (Ingles)

“I fixed this error, but now I have a problem. I cant connect with the MuGlobal client”

Ang nagsimula ng topic, 2017-08-08 (orihinal na salita)
RaGEZONE · 2017-08-08