MuADMINS
Soluciones
Arreglos breves para problemas comunes de servidores, clientes y sitios web de MU Online, cada uno con su fuente y su fecha. “Confirmado” significa que la persona que preguntó dijo que el arreglo funcionó.
1 solución para “dataserver” en Cliente del juego · Limpiar
Two separate servers (not subservers) both show in the client as server 1 with the same name
The client serverlist file was broken, not the server codes. 1. Replace the client Data serverlist.bmd with a working one (for example from another client of the same version) and edit th...
✓ Confirmado por el autor del temaTUServerMU · 2021-06-18
Más respuestas para “dataserver”
1 en Cliente del juego, 41 en otras categorías y archivos de servidor:
JoinServer and DataServer show "[SocketManager] WSAAccept() failed with error: 10061" on start.
1. Check DataServerAddress in common.dat. 2. Leave it at the default 127.0.0.1, it does not need your public IP. 3. Start the servers again.
✓ Confirmado por el autor del temaCreandoMU · 2022-02-21IGCN Season 12: DataServer says it cannot be run twice, though I start it only once
1. An earlier DataServer did not close properly and still runs hidden in the background. 2. Open Task Manager, find the DataServer process and end it (or simply restart the PC). 3. Start...
✓ Confirmado por el autor del temaRaGEZONE · 2019-02-22IGCN Season 12: DataServer is not responding although TCP/IP is enabled in SQL Server
1. Open DataServer.ini and check SQLServerName. 2. When SQL Server runs on the same machine use SQLServerName = (local) or the exact PC name as shown in SQL Server Management Studio (for...
✓ Confirmado por el autor del temaRaGEZONE · 2020-01-08IGCN S9 E2 repack: DataServer says 'Login failed for user ...' (SQLSTATE 28000) and 'DATA SERVER CANNOT CONNECT TO MSSQL'
1. The repack DataServer config came with a SQL login that does not exist on your SQL Server (here a random name like D2a78Rtko0), so the login fails. 2. Open the database settings of the...
✓ Confirmado por el autor del temaRaGEZONE · 2019-07-14DataServer floods '[QueryManager] State (24000) ... [ODBC SQL Server Driver] Invalid' when a character gets PK status (MuEmu S4 with the Ferrarezi website)
1. The cause was not ODBC: the Ferrarezi website adds a trigger Z_PK_HERO on dbo.Character that fires when PkCount changes, and its old version broke the DataServer queries. 2. In SQL Ser...
✓ Confirmado por el autor del temaRaGEZONE · 2018-04-09JoinServer and DataServer show Could not connect to database on start.
1. Restore the MuOnline database correctly in SQL Server (from the backup shipped with your files). 2. Create the ODBC data source the servers expect, pointing to that database. 3. Make s...
✓ Confirmado por el autor del temaTuServerMU · 2017-07-05Kayito MuEmu 0.97k download has no JoinServer and DataServer folders. Where are they?
1. First choose your database engine: SQL Server or MySQL. 2. For SQL Server copy JoinServer and DataServer from the MSSQL folder; for MySQL take them from the MySQL folder. 3. Put both n...
✓ Confirmado en el issueGitHub (nicomuratona/MuEmu-0.97k-kayito) · 2025-06-22Files 99b MC v3 on Windows 7 32-bit: DataServer shows "has stopped working" as soon as it starts.
1. Temporarily disable the antivirus or add the MuServer folder to its exclusions. 2. Open System Properties > Advanced > Performance Settings > Data Execution Prevention. 3. Pick Turn on...
✓ Confirmado por el autor del temaTuServerMU · 2018-01-09